Technical Comparison

Criteria Features FUETOR™ NEOGRAFT ARTAS
HarvestingScoring Rotating PunchRotating PunchRotating Punch
HarvestingHarvesting of Follicle Vacuum AssistedVacuum AssistedManual
HarvestingTitanium Coated Punch YesNoNo
HarvestingAvailable Sizes 0.6, 0.8. 1.0mm0.8, 1.0, 1.25, 1.4mmData Not Available
HarvestingLevel of Desiccation No DesiccationHighData Not Available
HarvestingChilled Wet Storage in the system YesNoNo
HarvestingPhysical Trauma to the follicles LowLowLow
HarvestingHigh Torque - low speed option (16:1) YesNoNo
HarvestingSuction Control YesYesNo
HarvestingDual Harvesting YesNoNo
HarvestingDepth Control YesYesYes
HarvestingHarvesting speed_Grafts per hr 1000600800
HarvestingUser Interface Touch Screen ElectronicsElectro-MechanicalComputer based
HarvestingAutomatic Graft alignment NoNoYes
HarvestingPatient Data Recording YesNoYes
HarvestingData retrieval YesNoYes
HarvestingSterilization AutoclaveAutoclaveData Not Available
ImplantationAvailability of Implanter YesYesNot applicable
Artas does not have any Implantation tool
ImplantationLoading of Follicular Units on Implanter SuctionSuctionNot applicable
Artas does not have any Implantation tool
ImplantationImplantation principle Knob Controlled PusherPressurised Piston PlungerNot applicable
Artas does not have any Implantation tool
ImplantationDepth Control by Surgeon's Choice AvailableNo controlNot applicable
Artas does not have any Implantation tool
ImplantationTrauma to follicular units Atraumatic_Tweezer s freeHighNot applicable
Artas does not have any Implantation tool
ImplantationSizes Available 0.6, 0.8. 1.0mm0.8, 1.0. 1.25, 1.4mmNot applicable
Artas does not have any Implantation tool
ImplantationPossibility of air contamination NoHighNot applicable
Artas does not have any Implantation tool
ImplantationDual Implantation YesNoNot applicable
Artas does not have any Implantation tool
ImplantationSterilization EtO sterilizedAutoclaveNot applicable
Artas does not have any Implantation tool
SystemSimultaneous Harvesting & Implantation YesNoNo
SystemWireless Foot Switch Control YesNoNot applicable
SystemFoot Print 380x450360x450mm686x1220
SystemHeight 10401200mm1727
SystemElectrical Specification 1 phase/100-240V AC1 phase/100V/115V-230VACData Not Available
SystemInstallation area required 6 ft x6 ft6 ft x6 ft10 ft x 10 ft
SystemInvestment required INR 25 Lakhs (USD 40K)INR 40 Lakhs (USD 67K)INR 1.20 Crores (USD 200K)
SystemCost Per Graft USD 1-2 USDUSD 5-7USD 7-10
SystemRunning Cost (Consumables only) INR 5,350INR 8,000INR 1,20,000
SystemLocal Support AvailableNot availableNot available
SystemTraining / Skill Required LowLowHigh
SystemReplacement Warranty AvailableNot availableData Not Available
Fuetoris protected by various granted and pending Patents, Trademark and Copyrights, comprising of PCT/IN2015/050042 - HAIR TRANSPLANT SYSTEMS AND METHODS OF THEIR USE, PCT/IN2015/050092 - BIOMEDICAL DEVICE FOR IMPROVED DESICCATION TOLERANCE OF GRAFTS, PCT/IN2015/050091 - BIOMEDICAL DEVICE FOR IMPLANTING GRAFTS, PCT/IN2015/050112 - BIOMEDICAL DEVICE FOR HARVESTING GRAFTS, PCT/IN2015/050201 - Graft Tray, Trademark Application no - 2726084 & 2726085 and Copyrights. All rights are reserved with Veol Medical Technologies Pvt. Ltd.